2-Quadrant BLDC Driver With Variable Parameter Settings And High Current
Get the Flash Player to see this player.
   
                             35A/50A                                                75A/100A
Also Offer
*2-Quadrant BLDC Driver With Variable Parameter Settings
*2-Quadrant BLDC Driver With Fixed Parameters

Download

Note:

1.Control signals:
F/R-----H or Open=Forward, L or Close=Reverse
EN------H or Open=Disable, L or Close=Enable
BK------H or Open=Running, L or Close=Brake
SV------0~5V speed reference(112K input resistance)
PG-----Speed pulse output(OC)
ALM---Alarm output(OC)

2. Hall sensors cable can not be tied together with windings cable.

3. Alarm conditions:
a. Hall sensor signals are not correct.
b. LV or OV for 2~3S.
c. Short circuit and Over temperature of case.
d. Over load for 6s continuously.
e. It can be reset by Turn-Off-On DC Power or Disable the driver once.

4. LED indicator:
SC--------Bright=Short circuit , Dark=driver is OK
P/A-------Bright=Driver is OK, Blink=Driver is in alarm
SHAFT----Bright=Motor shaft is moving, Dark=Motor shaft is in static

5. Braking operation:
The motor speed must be less than the safe brake speed Ns when you brake the motor.
For Y windings, Ns=√3 x Ip x RL x N/ (2x Vp)
For △windings, Ns=IP x RL x N/ (2 x √3 x Vp)
Ip=Peak current(A), RL=Line to line resistance of windings(Ohm)
N=No-load speed(rpm), Vp=Rated voltage(V), Ns=Safe brake speed(rpm)

6. Safe F/R:
If you change F/R of the driver rapidly, it will stop the power stage and motor will be free until the speed is detected as zero,and then to drive in correct direction. This means smooth reverse.

7. Safe start:
If the motor speed is not detected as zero at power on, the driver will be free until the motor speed is zero.

8. Driver setup by pot and switch:








































R-SV pot=SV voltage ratio, R-LG pot=Loop gain, R-PC=Peak current ratio, R-RT pot=Ramp time
SW1=60/120 Hall sensors, SW2=Open/Close loop, SW3,4=Speed/Current loop, SW5=Loop filter time, SW6=SV ramp time setting, SW7,8,9,10=Speed range setting.

9. Peak current selection:
Ip>=2xIr or Ip>=4xPo/Vp, Ip is peak current of driver(A), Ir is rated current of motor(A)
Po is rated output power of motor(W), Vp is rated voltage of driver(V)
Dimension:

 